Micro-Seal SiH4 100% Silane Deep Penetrating Water Sealer | UV Resistant | Co…

Micro-Seal SiH4 100% Silane Deep Penetrating Water Sealer | UV Resistant | Co…

USD 138.00 USD
SKU: mbT4JuId
Condition: New

Specifications

Return Shipping Will Be Paid ByBuyer
All Returns AcceptedReturns Accepted
Item Must Be Returned Within30 Days
Refund Will Be Given AsMoney Back
TypeDoes not apply
BrandDoes not apply

      Micro-Seal SiH4 100% Silane Deep Penetrating Water Sealer | UV Resistant | Concrete | Stucco | EIFS | CMU Block | Clay Tile    Micro-Seal SiH4 100% Silane Deep Penetrating Water Sealer | UV Resistant | Low VOC | Concrete Stucco EIFS CMU Block Clay Tile Micro-Seal SiH4 100 is a 100% silane sealer designed to penetrate deeply into concrete and a variety of porous masonry substrates to prevent moisture intrusion, salt-ion intrusion, staining and freeze/thaw damage. This high solids 100% Silane water repellent provides protection from mold, mildew, and efflorescence. Due to the small particle size, it penetrates deeper than Silane Siloxane blended and Siloxane formula water repellents for longer lasting protection and superior performance. The depth of penetration can be controlled based on application spread rates and how much is applied. Ideal for concrete and masonry substrates due to it’s reactive nature that chemically bonds with the substrate. Micro-Seal SiH4 100 is not affected by UV light and wind-driven rain. What makes Micro-Seal SiH4 different? A proprietary ingredient called Micro-Lok™. This additive ensures a long lasting mechanical bond and creates a hydrophobic barrier not affected by weathering, salt, dirt, freezing temperatures, UV light and wind-driven rain. Micro-seal SiH4 is a penetrating silane sealer invisible after application as it penetrates completely below the surface. Available in two size options, 1 gallon and 5 gallons, Micro-Seal SiH4 Silane is supplied Ready-to-Use. Primer: For masonry surfaces, recommended Restore-N-Prep as pretreatment to properly clean the surface. Topcoat: None Required. WHERE IS MICRO-SEAL SiH4 SILANE USED? Construction & Remodel Projects: Exterior Buildings | Retaining Walls, Warehouse | Factory | Parking Garage Floors, Bridge Abutments, Stadiums Homeowner Projects: Exterior brick|stucco walls, chimneys, driveways, garage floors, decks, patios, porches, walkways, fences. Non-Traditional Applications: Clay tile roofs, clay|concrete flower pots, indoors floor and bathroom tile mortar grout sealing WHY MICRO-SEAL SiH4 SILANE? Small Particle Size for Deeper Penetration and longer lasting results Will not yellow, haze, crack or peel Overspray Does not etch metal or glass No film formation - does not change looks of the surface Allows substrates to breathe without trapping moisture Reduces rebar rusting in concrete and surface erosion from salts Can be subjected to wheeled or vehicular traffic immediately after application COVERAGE RATE The coverage depends on the surface. Test the product on a small area of the substrate to estimate coverage. Extremely porous surfaces may require multiple coats. The use of fluted, scored block, raked joints, sandblasted or etched surfaces will result in greater absorption and lower coverage rates, by up to 40%. Test these areas for the expected coverage rate before general application. Allow for this increased surface area when determining material requirements. Substrate Sq Ft/ Gallon CMU & Block 60-90 Adobe Block & Natural Stone 80-100 Clay Brick 135-160 EIFS 90-130 Stucco 110-160 Concrete 145-170 Concrete Curing 320-420 Technical Data Material Type Silane Active Content 100% Volume Solids 85% Color of Material Milky White Odor No Odor VOC 30 g/L Flash Point Non-Flammable pH Value 6 Viscocity 9.6 Seconds No. 4 Ford Cup Weight Approximately 8.8lbs per Gallon Surface Dry/Recoat Approximately 1 Hour Full Chemical Cure 5-7 Days Test Data ASTM C666 2200 Cycles- No Effect ASTM C672 100 Cycles No Mass Loss, No Scaling ASTM D2243 Do Not Freeze ASTM G154 2,500 Hours No Loss in Repellency Wind Driven Rain ASTM E-514-86., 98.7% Leak Red Water Pen Fed Spec SS-W-110C, 75% Min Req, 96.8 Leak Red Chloride Ion Intr Salt Pounding NCHRP No. 244 Series IV – 95% Red No. 244 Series II – 87% Red Chloride Ion Absorption No. 244 Series II – 87% Water Abs CMU ASTM C140-75 98.6% Effective Water Vapor Trans ASTM D-1653-71 100% Vapor Perm Water Repellency ASTM C67-87 98.6% Effective Weathering ASTM G-53 3,500 Hours – No Change Surface Burning ASTM E84 Flame Spread 0, Smoke Development 0 Approvals & Qualifications LAUSD – OESH Approved USGBC – LEED Points Up to 3 Points LEED (New Construction) Approved LEED (New Schools/CHPS) Approved CARB Approved SCAQMD Approved FDA Meets Requirements USDA Meets Requirements APPLICATION INSTRUCTIONSFOLLOW THESE SIMPLE APPLICATION STEPS Surface Preparation: Prior to application, all surface shall be clean and dry with no oils, dirt, debris, or minerals such as efflorescence, lime and calcium. These stains, along with others, will prevent proper penetration of Micro-Seal® SiH4 to sufficiently seal for the warranty period. The use of Rainguard’s Restore-N-Prep™ Concrete and Masonry Cleaner system is recommended as a pretreatment to clean masonry surfaces. Once clean, allow the surface to fully dry before sealing or applying a topcoat (See the Restore-N-Prep™ TDS for details). Application Instructions 1. Apply Micro-Seal® SiH4 using a hand pumped garden sprayer (do not atomize) or low-pressure airless spray equipment. 2. If using airless spray equipment we recommend a spray tip size of .035 to .051. Spray head should be held 8 to 12 inches from the surface. 3. Apply a flood coat to the point of saturation. This is achieved when the material is dripping 8-12 inches from the point of application. 4. Apply material following the coverage rate previously listed (P.1). 5. Avoid application in windy weather. 6. Trigger gun off at the end of each pass to avoid using excessive materials. 7. Multiple coats may be applied. Whitening or yellowing will not occur. Safe Handling: Use product only with adequate ventilation and/or an appropriate cartridge type respirator. Avoid contact with skin and wear protective gloves. Read the Safety Data Sheet before using. Precautions: Use material in a well-ventilated area. Protect the work of other trades. Protect shrubbery and other plants with drop cloths. Protect automobiles and all other areas not to be coated from overspray. Remove overspray from any windows, automobiles, metal, etc. as soon as possible should it occur. To prevent permanent staining, clean spills or leaks in a timely manner. All surfaces to be coated should be clean of any dirt and grime, efflorescence, lime run, form oils and release agents, grease, mud, excess mortar, and mold and mildew,etc. All cracks should be pointed or caulked. All voids, beeholes, masonry surface defects and openings such as conduits, pipes, drains, door frames, vents, air conditioner openings, electrical openings, control joints, or any dissimilar materials should be repaired using urethane or other approved patching. Do not apply to surfaces if moisture content is greater than 25% as measured with an electronic moisture meter. Do not apply materials in climates where freezing temperatures have existed prior to application. Allow adequate time for surfaces to thaw. Establish that air, surface, and material temperatures are above 40°F (4.4°C) and at least 5°F above the dew point prior to painting. Do not apply at temperatures below 40°F when temperatures are expected to drop below 40°F within 48 hours of application. Do not apply if rain, snow, or lower temperatures are expected within 48 hours. Do not apply if relative humidity is greater than 90%. Clear water repellents are not designed to waterproof horizontal masonry surfaces such as ledges, sills, cornices and parapet walls, etc. Store materials in a well-protected area at 45°- 90°F. Avoid freezing temperatures, direct sunlight, and moisture. Keep away from heat sources. NOTICE TO BUYER: DISCLAIMER OF WARRANTIES AND LIMITATIONS ON OUR LIABILITY We warrant that our products are manufactured to strict quality assurance specifications and that the information supplied by us is accurate to the best of our knowledge. Such information supplied about our products is not a representation or a warranty. It is supplied on the condition that you shall make your own tests to determine the suitability of our product for your particular purpose. Any use or application other than recommended herein is the sole responsibility of the user. Listed physical properties are typical and should not be construed as specifications. NO WARRANTY IS MADE, EXPRESSED OR IMPLIED, REGARDING SUCH OTHER INFORMATION, THE DATA ON WHICH IT IS BASED, OR THE RESULTS YOU WILL OBTAIN FROM ITS USE. N0 WARRANTY IS MADE, EXPRESSED OR IMPLIED, THAT OUR PRODUCT SHALL BE MERCHANTABLE OR THAT OUR PRODUCT SHALL BE FIT FOR ANY PARTICULAR PURPOSE. NO WARRANTY IS MADE THAT THE USE OF SUCH INFORMATION OR OUR PRODUCT WILL NOT INFRINGE UPON ANY PATENT. We shall have no liability for incidental or consequential damages, direct or indirect. Our liability is limited to the net selling price of our product or the replacement of our product, at our option. Acceptance of delivery of our product means that you have accepted the terms of this warranty whether or not purchase orders or other documents state terms that vary from this warranty. No representative is authorized to make any representation or warranty or assume any other liability on our behalf with any sale of our products. Our products contain chemicals that may CAUSE SERIOUS PHYSICAL INJURY. BEFORE USING, READ THE MATERIAL SAFETY DATA SHEET AND FOLLOW ALL PRECAUTIONS TO PREVENT BODILY HARM. Size Price 1 Gallon 138.00 5 Gallons 684.25   Shipping Shipping cost:No cost shipping lower 48 US States FedEx Ground Delivery time:Typically 3-5 days to process order plus 1 to 5 days  transit time after shipment depending on location Payment We accept the following payment methods: PayPal payment due at time of order placement Please contact us if you have any questions. Service PLEASE CONTACT CUSTOMER SERVICE FOR QUESTIONS 

Related Items